# Solid wood flooring

> Solid wood flooring is made of boards cut from one piece of timber, top to bottom, so it can be sanded and refinished many times. In the United States ¾ in is the most common thickness. It suits rooms on or above ground, and it needs a stable indoor climate, particularly over underfloor heating.

Source page: https://www.misterendgrain.com/flooring/solid-wood/
Updated: 2026-11-03

| Fact | Value |
|---|---|
| Construction | A single piece of wood from top to bottom [1] |
| Most common thickness | ¾ in (US industry-average study) [2] |
| Face-width classes | Strip: under 3 in. Plank: 3 to 5 in. Wide plank: over 5 in [2] |
| Refinishing | Can be sanded and refinished numerous times during its service life [2] |
| Example product (Junckers) | 14 mm or 22 mm thick, 129 mm wide, two rows of staves joined by a glued double dovetail [6] |
| Below ground level | Should not be installed below grade unless the manufacturer says otherwise [3] |
| European product standard | EN 13226, solid parquet elements with grooves and/or tongues (2009 edition withdrawn 4 December 2024, revised by EN 13226:2024) [8] |

Solid wood flooring is exactly what the name suggests: boards cut from one piece of timber, so the wood runs unbroken from the surface to the underside [1]. Because there is no separate wear layer to wear through, a solid floor can be sanded and refinished numerous times during its service life [2]. In the United States, ¾ in is the most common thickness [2].

## What is solid wood flooring?

The National Wood Flooring Association (NWFA) defines solid wood flooring as "a solid piece of wood from top to bottom" [1]. It is one of three categories in the NWFA's definition of real wood flooring, alongside [engineered wood flooring](https://www.misterendgrain.com/flooring/engineered-wood/) and composite engineered flooring, which has real wood only on the wearable surface [1]. For a detailed point-by-point evaluation of their structural and heating differences, read our guide to [engineered vs solid wood flooring](https://www.misterendgrain.com/guides/engineered-vs-solid-wood/).

Solid boards come as strips, planks and wide planks. In the NWFA's industry-average study, a board is classed as strip when its face is under 3 in wide, plank when it is between 3 and 5 in, and wide plank when it is over 5 in [2]. See our page on [wide plank flooring](https://www.misterendgrain.com/flooring/wide-plank/) for how width affects movement and installation. The same study counts parquet, including herringbone and chevron, as solid flooring too: parquet is any pattern that is geometric rather than linear [2].

Some solid floors are not a single strip of timber at all. Junckers, for example, makes its solid hardwood boards from two rows of staves joined by a glued double dovetail, in 14 mm and 22 mm thicknesses and a 129 mm width [6]. That is one manufacturer's construction, but it shows that "solid" describes the wood through the thickness, not a single sawn plank.

## How thick is solid wood flooring?

The NWFA study names ¾ in as the most common thickness [2]. Thinner solid flooring exists. The NWFA's installation guidelines refer to a "thin-classification" of solid flooring that is less than ¾ in thick, and they say that over a solid-board subfloor it needs either a replacement subfloor or a double-layer subfloor system [3].

In metric markets the figures differ. Junckers lists nominal thicknesses of 14 mm and 22 mm, with measured values of 13.8 mm and 21.8 mm (each within 0.2 mm) [6]. Always check the thickness against the subfloor and installation method the manufacturer allows.

## How many times can solid wood flooring be sanded?

The honest answer is that the industry body publishes no single number. The NWFA says only that solid wood "can be sanded and refinished many times" [4]. Its consumer guidance on refinishing says the number of times a floor can be sanded varies with contractor skill, equipment, wear layer thickness, floor flatness and floor condition, and it gives no figure [5].

Manufacturers do quote counts for their own products. Junckers states that, because there is no thin wear layer, its floors may be sanded between eight and ten times [7]. Treat that as a claim about one product range, not a rule for every solid floor. If you plan to refinish, read our [guide to sanding and refinishing](https://www.misterendgrain.com/guides/sanding-and-refinishing/) first.

## Where does solid wood flooring suit?

Solid wood is intended for rooms on or above ground. The NWFA's consumer site says it "can be used in any room that is on or above ground" [4], and its installation guidelines say solid wood floors should not be installed below grade, meaning below ground level, unless the manufacturer recommends otherwise [3]. For basements the NWFA's consumer site points to engineered flooring instead, describing it as ideal for basement installations [4].

Solid wood can be fixed in several ways. The NWFA guidelines have separate chapters for glue-down, nail-down and floating installation, and the method depends on the product and the subfloor [3]. Our [guide to installation methods](https://www.misterendgrain.com/guides/installation-methods/) explains the choices.

## What are the humidity and underfloor heating limits?

Wood takes up and gives off moisture, so a solid floor moves as conditions change [3]. As a general rule for solid wood, the NWFA defines appropriate conditions as an interior kept between 30% and 50% relative humidity and between 60 and 80 degrees Fahrenheit. It adds that some manufacturers dry their products to higher moisture contents (8 to 13%) or lower ones (4 to 9%) for different regions, and that in some climates the ideal humidity range is 45% to 65% or 20% to 40% [3].

For underfloor (radiant) heating the NWFA says most wood flooring can be installed over radiant heat if every necessary condition is met. Its guidelines add several limits [3]:

- Flooring made for a moisture content above 9%, or for conditions above 50% relative humidity, should not be used over radiant heating unless the manufacturer recommends it.
- Narrow boards move less than wider boards of the same species and cut, and quartersawn or riftsawn flooring is more stable in width than plainsawn.
- Less stable species such as hickory, beech and maple are less suitable over radiant heat.
- Subfloor surface temperature should never exceed 80°F at installation.
- A supplemental humidity control system is often necessary to hold 30% to 50% relative humidity.

Manufacturers do not all agree on solid versus engineered stability. The NWFA states that engineered flooring is in general more dimensionally stable than solid, though not every engineered product suits radiant heat [3]. Junckers, a maker of solid floors, takes the opposite view for its own boards, saying engineered floors are not more stable than its floors and that it has guaranteed its solid floors for underfloor heating for about 30 years [7]. Those are company statements, so follow the specific manufacturer's written conditions. Our [underfloor heating guide](https://www.misterendgrain.com/guides/underfloor-heating/) and [moisture and acclimatisation guide](https://www.misterendgrain.com/guides/moisture-and-acclimatisation/) cover the practical steps.

## Which standards apply?

In Europe, solid parquet elements with grooves and/or tongues are covered by EN 13226. The 2009 edition was withdrawn on 4 December 2024 and has been revised by EN 13226:2024 [8]. The umbrella standard EN 14342 sets the characteristics, conformity evaluation and marking requirements for wood flooring and parquet, and it refers to the individual product standards [9]. Our overview of [flooring standards](https://www.misterendgrain.com/guides/flooring-standards/) puts these in context. Species also matter, so compare options such as [European oak](https://www.misterendgrain.com/species/european-oak/) before you choose.

Appearance is a separate choice from construction: our guide to [wood flooring grades](https://www.misterendgrain.com/flooring/wood-grades/) explains how oak is graded from Clear to No. 2 Common, and [wood stairs and nosings](https://www.misterendgrain.com/flooring/wood-stairs-and-nosings/) covers solid treads.

## Frequently asked questions

### What is the difference between solid and engineered wood flooring?

Solid wood flooring is one piece of wood from top to bottom. Engineered flooring is real wood too, but it is built from several bonded layers, with a wear layer on top [1]. Engineered floors can be sanded and refinished, but not as many times as solid wood [4].

### How many times can solid wood flooring be sanded?

The National Wood Flooring Association says solid wood can be sanded and refinished numerous times but gives no fixed number [2]. One manufacturer, Junckers, states that its solid floors may be sanded between eight and ten times because they have no thin wear layer; that is the maker's own claim for its own product [7].

### Can solid wood flooring go in a basement?

Usually not. NWFA guidelines say solid wood floors should not be installed below grade unless the manufacturer recommends it [3]. NWFA's consumer site says solid wood suits any room on or above ground [4].

### Can solid wood flooring be used over underfloor heating?

Sometimes. NWFA says most wood flooring can be installed over radiant heat if the conditions are met, but flooring made for moisture content above 9%, or for conditions above 50% relative humidity, should not be used unless the manufacturer says so [3].

## Sources

1. [NWFA Announces Official Definition of Real Wood Flooring](https://nwfa.org/nwfa-announces-official-definition-of-real-wood-flooring/), National Wood Flooring Association, accessed 2026-11-03
2. [Environmental Product Declaration: Solid Wood Flooring (industry average)](https://nwfa.org/wp-content/uploads/2024/12/Solid_Wood_Flooring_EPD.pdf), National Wood Flooring Association / ASTM International, accessed 2026-11-03
3. [Wood Flooring Installation Guidelines (revised 2025)](https://nwfa.org/wp-content/uploads/2026/02/NWFA-Installation-Guidelines.pdf), National Wood Flooring Association, accessed 2026-11-03
4. [Types of Wood Floors](https://woodfloors.org/types-of-wood-floors/), National Wood Flooring Association (woodfloors.org), accessed 2026-11-03
5. [Refinishing Your Floors](https://woodfloors.org/refinishing-your-floors/), National Wood Flooring Association (woodfloors.org), accessed 2026-11-03
6. [2-Strip Solid Hardwood Floors: product information](https://www.junckers.com/wood-flooring/guidance/technical-advice/product-data-sheets/b-product-information-solid-hardwood-floors/2-strip-solid-hardwood-floors-product-information-b-2-0), Junckers, accessed 2026-11-03
7. [Solid versus engineered floors FAQ](https://www.junckers.co.uk/wood-flooring/guidance/solid-vs-engineered-floors-faq), Junckers, accessed 2026-11-03
8. [EN 13226:2009 Wood flooring - Solid parquet elements with grooves and/or tongues](https://genorma.com/en/standards/en-13226-2009), Genorma (CEN standards catalogue), accessed 2026-11-03
9. [EN 14342:2013 Wood flooring and parquet - Characteristics, evaluation of conformity and marking](https://genorma.com/en/standards/en-14342-2013), Genorma (CEN standards catalogue), accessed 2026-11-03